Product Usage
The Horizontal Cold and Hot Shock Test Chamber is used to evaluate the ability of material structures or composite materials to withstand rapid alternating exposure to extremely high and low temperatures. It tests the chemical and physical damage caused by thermal expansion and contraction within a very short time. The sample remains completely stationary during testing, which is the current standard method for electronic component testing, research applications, and large-scale screening in semiconductor production lines. This approach significantly reduces material consumption and testing costs. It features fast operation and high reliability. Suitable for testing metals, plastics, rubber, electronics, aerospace materials, and more.
Test Standards
-
GB/T2423.1-2001: Test A - Low Temperature Test Method
-
GB/T2423.2-2001: Test B - High Temperature Test Method
-
GB/T2423.22-2002: Test N - Temperature Change Test Method
-
GJB/150.3-1986: High Temperature Test
-
GJB/150.4-1986: Low Temperature Test
-
CJB/150.5-1986: Temperature Shock Test
Product Parameters
| Parameter |
Specification |
| Model |
CTS-280L |
| Pre-cooling Temperature Range |
-10℃ to -65℃ |
| Pre-heating Temperature Range |
Room Temperature (RT) to +180℃ |
| Temperature Shock Range |
-40℃ to +150℃ |
| Temperature Fluctuation |
≤ ±0.5℃ |
| Temperature Uniformity |
≤ ±2℃ |
| Heating Time (High Temp Chamber) |
RT to 180℃ in less than 50 minutes, overall average non-linear |
| Cooling Time (Low Temp Chamber) |
RT to -65℃ in less than 80 minutes, overall average non-linear |
| Heating Overshoot |
≤ 2℃ |
| Maximum Load |
Equivalent to 5kg aluminum block, electrical heating 1000W |
| Temperature Transition Time |
≤ 10 seconds |
| Temperature Shock Recovery Time |
≤ 5 minutes |
| Minimum High/Low Temperature Holding Time |
30 minutes or more |
| Inner Chamber Size (W×H×D) |
700 × 500 × 800 mm |
| Outer Chamber Size (W×H×D) |
2500 × 2100 × 1800 mm |
| Inner Chamber Material |
SUS304# Mirror Finish Stainless Steel Plate |
| Outer Chamber Material |
Cold Rolled Steel Plate with Electrostatic Powder Coating |
| Insulation Material |
Rigid Foam + Fiberglass |
| Refrigeration System |
French Tecumseh Fully Sealed Piston Compressor or German Imported Semi-Sealed Compressor |
| Standard Configuration |
Test hole Ø50 mm (1 on left side), 2 sample racks layers |
| Safety Devices |
Fuse-free switch, compressor overpressure, overheat, overcurrent protection, overtemperature protection, high-pressure protection, etc. |
| Power Supply |
AC 380V, 22KW |